For optimum pipe laying, a systematic bedding structure is required in the pipe trench, as shown in the adjacent scheme corresponding to DIN EN 1610 / IS 16098-2. The lower bedding [a] and the top bedding [b] both carry the pipe. Therefore, careful completion and sealing according to the load calculations are required. The height of the top bedding results from the bedding or support angle. This term is still widely used and characterizes in an easily comprehensible manner the carrying capacity of the bedding. The main compression directly above the pipe should be realised by a 20 to 30 cm cover layer [c] on top of the pipe soffit.The GIGACOR system must be laterally protected to a high degree by soil compression.

The following basic values are taken as a basis for the calculation of the sample statics

  • Traffic load: SLW 60 with asphalt or concrete surface
  • Additional area load
  • Embedment E 20
  • Laterally applied soil E3
  • Cover E1
  • Lower trench E4
  • Slope angle or embankment
  • Ground water level
  • The very smooth, pore-free surface of the material prevents the formation of deposits and incrustation.
  • Average surface roughness values during service of k = 0.25 in combination with excellent hydraulic behavior of the pipe surface.
  • Well-balanced ring stiffness and ring flexibility: GIGAPIPE SYSTEMS tests the GIGACOR successfully with a deformation of up to 30 % and a ring stiffness of up to SN 8

giga pipes

Standardisations and Test certifications

It is fully in line with GIGAPIPE SYSTEMS’s commitment to quality to guarantee the customer-oriented performance of all our products not only through our own quality management, but also by means of external quality control and third party certifications.

giga pipes

Chemical resistance

  • DIN 8078, supplementary sheet 1.
  • The durability of pipes, fittings and sealing elements with pH values ranging between pH 2 (acidic) and pH 12(alkaline) is guaranteed without any restriction.
  • The resistance against wastewater and soil substances according to DIN 1986 is proven.

Thermal tolerances

  • All pipe sections and fittings are design

Identification marking according to IS 16098-2, DIN EN 13476

  • Black outer profile
  • Optional Inner surface in any colour – optimally suited for in-pipe camera inspections.
  • Optional Two coextruded line marks for subsequent identification in the excavation: red – waste water or combined sewers, blue – storm water sewer.

Nominal widths (DN) and lengths

  • The GIGACOR system is available in the following nominal diameters: 150, 200, 250, 300, 400 and 500
  • Standard length without inline bell: 6,000 mm.
  • Special lengths available upon request.
  • During installation, the pipes are cut off individually without special accessories.

Recycling

  • At the end of their lifecycle, all pipes and fittings of the
    GIGACOR system can be recycled unrestrictedly